Utility Cost and Tariff Bundle

Make utility bills understandable, catch errors, and identify the biggest cost levers (rate plan vs demand vs behavior).

Run the OperationBundleBundle90 min to 2 weeks
Disclaimer: Educational only. Tariff rules vary by utility and jurisdiction. Use this as a directional operational bundle, not a regulatory determination.

Outcome

By the end of this bundle you will:

  • Compute a clean baseline from utility bills: blended $/kWh and demand share
  • Identify common billing errors and process gaps that create avoidable cost
  • Prioritize the biggest levers: billing fixes, demand management, and rate/tariff optimization
  • Establish a repeatable monthly bill review routine with evidence links

Who this is for

  • Facilities/operations teamsthat manage utilities
  • Finance/AP teamspaying utility bills and handling disputes
  • Sustainability teamsbuilding Scope 2 datasets and evidence binders
  • Anyonetrying to reduce "utility bill surprises"

Time to implement

90 minutes

One high-cost site (one bill period) end-to-end

2 weeks

Standardize for top 10 sites by spend and create a monthly routine

What you'll need

  • 6–12 months of bills for at least one site (PDFs or portal exports)
  • Utility account identifiers (account number, service address, meter ID if available)
  • A stable evidence folder (so bills and exports are not trapped in email)
  • Optional but helpful: knowledge of the site's major loads (HVAC, process, EV charging)

Step-by-step sequence

1Secure access + evidence storage (do this first)

If you can't consistently retrieve bills, you can't improve anything.

  • • Confirm portal access owner and backup owner
  • • Create a standard folder path for this site/account
  • • Store the bill PDF/export for each month

(If access is messy, use the Utility Account Access & Inventory Playbook.)

2Turn the bill into simple metrics

Use the Blended Electricity Rate & Demand Share Calculator to compute:

  • • Blended $/kWh
  • • Demand share %
  • • Energy share %
  • • Other charges %

Goal: separate "this is a demand problem" from "this is a rate/energy problem."

3Run the Billing Error Checklist (fast ROI)

Check for common, high-frequency issues:

  • • Wrong customer class / rate schedule
  • • Billing period overlaps or missing days
  • • Duplicate charges or estimated reads repeated
  • • Unexpected riders/fees that need explanation
  • • Late fees driven by internal AP process gaps

Log issues and track resolution.

4Identify the top levers (prioritize)

Use your calculated outputs to choose the correct lever:

If demand share is high (often >20–30%):

Peak management and load shifting likely matters (go to the Peak Demand Bundle)

If blended $/kWh is unusually high:

Rate schedule evaluation and TOU strategy likely matters (tariff optimization)

If "Other" is unusually high:

Investigate riders, taxes, fees, penalties, and billing mistakes

5Build a repeatable monthly bill review routine

Minimum routine:

  • Every month: compute baseline metrics and store evidence link
  • Every month: flag anomalies (spikes/drops) and log issues
  • Monthly or quarterly: review top 10 sites by cost and decide actions

Included assets

Recommended "evidence discipline"

  • • Store each bill and/or usage export with a stable link
  • • Record billing start/end dates (not just "month name")

Templates (copy/paste)

  • • Utility bill review log
  • • Billing error checklist
  • • Top levers (per-site action list)
  • • Monthly utility review agenda

↓ See templates section below

Templates (copy/paste)

1) Utility Bill Review Log

SiteUtility providerAccount #Period startPeriod endTotal $Total kWhBlended $/kWhDemand $Demand %Other $Issue foundActionOwnerDueEvidence link

Beginner note:

If you don't have demand $ broken out, leave it blank for now. You can still compute blended rate and start tracking.

2) Billing Error Checklist (operational)

Billing Error Checklist

Rate / classification
- Does the rate schedule/class match the site type?
- Any recent changes that need explanation?

Period integrity
- Billing period dates present?
- Overlaps or gaps vs prior bill?

Charges
- Demand charges present and consistent with expectations?
- Any unusual riders/fees?
- Late fees or penalties? (process issue)

Reads / usage
- Estimated read repeated?
- Usage spike/drop without explanation?

Evidence
- Bill PDF stored with stable link?
- Key fields captured (dates, kWh, $)?

3) Top Levers (per-site action list)

Utility Cost Levers (per site)

Fast fixes (0–30 days):
- billing dispute / error correction
- rate schedule/class verification
- AP process fix to eliminate late fees
- secure portal access and evidence storage

Operational levers (30–90 days):
- schedule enforcement (hours of operation)
- peak management and load shifting
- basic setpoint and sequencing tuning

Tariff/rate levers (90+ days):
- TOU strategy improvement
- rate schedule change (where eligible)
- interval data strategy for deeper optimization

4) Monthly Utility Review Agenda (20 minutes)

Monthly Utility Review (20 min)

1) Top 5 cost sites this month (5 min)
2) Any major anomalies? (5 min)
3) Demand share leaders (peak targets?) (5 min)
4) Billing disputes and actions status (5 min)

Outputs:
- Updated utility bill review log
- Owners + due dates for actions
- Sites escalated to Peak Demand Bundle or Tariff review

Proof and KPIs

  • # sites reviewed per month
  • % sites with evidence-linked bills for the period
  • $ recovered from billing errors (track where possible)
  • blended $/kWh trend (portfolio and top sites)
  • demand share trend (where available)

Common pitfalls

  • No portal access owner (data gaps persist)
  • Comparing bills with mismatched periods
  • Ignoring demand charges because they "seem complicated"
  • Fixing one-off bills without creating a routine (problems repeat)
  • Storing bills in email threads instead of evidence folders

Next bundles to run

Peak Demand Bundle

If demand share is meaningful

Coming soon

Scope 2 Data to Claims Bundle

If reporting/claims are a priority

Coming soon

Change log

v1.0 (2026-01): Latest release